Customization: | Available |
---|---|
After-sales Service: | Yes |
Warranty: | Yes |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Engine: KINGPOWER KP6V132J 290kW Methanol Engine
Alternator : 200kW Alternator
Control System: Intelligent control module
Options (open type / silent type / container type )
Cooling system: Engine with closed radiator and fan cooling system
Speed control system: Electronic control
Intake system: engine with air filter and connecting pipeline
Fuel System: (GB/T23510-2009)Methanol. Amonge them,only methanol can be used when the ambient temperature is 16ºC .when the ambient temperature is lower than 16ºC,cold starting measures must be used at the same time during the starting stage,such as:water jacket heater,heating pot,etc,the engine water temperature can be started after rising to more than 25ºC .
Lubrication system:when the engine leaves the factory ,there is no lubricating oil,and lubricating oil should be added through the lubricating oil filler.The first filling volume is about 38 L,and the actual operation shall be subject to the scale of the dipstick.The engine must use methanol special lubricating oil for heavy load power transmission.The viscosity grade of lubricating oil shall be selected according to ambient temperature and service conditions.
Viscosity grade:
a) When the ambient temperature is above -20ºC, 10W-40 special lubricating oil for heavy load power transmission methanol is used,and 15W-40 special lubricating oil for heavy load power transmission methanol is allowed for bench test;
b)The ambient temperature is -20ºC ~-30ºC , and 5W-40 special lubricating oil for heavy load power transmission methanol is used;
c )When the ambient temperature is below -30ºC , 0W-40 special lubricating oil for heavy load power transmission methanol is used;
In use,0W-40 is allowed to replace 5W-40 and 10W-40,5W-40 to replace 10W-40 and 15W-40, 10W-40 to replace 15W-40.
Power system: power output using electric operation/manual operation(optiongal)air switch output
Start system: low temperature battery and connection cable (24V start)
Smoke exhaust system: engine exhaust with muffler, smoke exhaust bend and other connected pipelines
Security system: with Mains floating charger
2. Technical specification of engine
Structural form:V-type 90° ,6-cylinder ,4-stroke ,4-valve ,intake manifold premixed ,spark ignition ,supercharged intercooled ,electronically controlled water-cooled engine.
Dimensions: 1115 mm×920 mm×1300mm
Wight: 950 kg
Power/speed: 290kW/1500r/min
Idle: 700 r/min±50 r/min
Methanol consumption rate under rated condition:≤415g/kWh
Oil consumption rate: ≤0.3% of Methanol consumption rate
Noise: ≤108dB
Vibration: displacement≤309.08μm ,speed≤35.29mm/s ,acceleration≤15. 10m/s2
3. 1 basic parameters and performance
Methanol generator set: KP200GFS
Rated Power: 200 kW
Sandby-Power:220 kW
Rated Voltage: 400/230V
Phase No :3 P/4 W
Rated frequency : 50HZ
Power Factor : cosФ=0.8(lag)
Steady-state voltage deviation :±2.5%
Steady-state frequency band:±1.5%
Transient voltage adjustment rate: + 25% -- -20%
Transient frequency regulation: +12%---20%
The no-load voltage setting range of Genset is 95% ~105%.
Other parameters meet the requirements of G1 in GB / t2820.5. After intercooling, the temperature is controlled at 50 ºC ± After 5 ºC, the steady-state frequency fluctuation meets the requirements of G2 in GB / t2820.5 and can be operated in parallel.
3.2 Alternator
Atmospheric pressure: 1 standard atmosphere
Relative humidity: 30%;
Ambient temperature: 0ºC~60ºC
Altitude: ≤1000 m;
4.Control System
Control panel power : 24V DC; Current: 0. 1 A to 0.4 A
Control screen working environment:
temperature: -40ºC--+70ºC; Humidity: 90%RH Max at 40ºC .
control system is widely used in telecommunications, high-speed, power supply, national defense and other fields.The control panel can realize the function of Genset start and stop.
Genset operating parameters detection shows: voltage, current, frequency, power factor, apparent power, active power, oil pressure, battery voltage, starting times, Genset operating time, coolant
temperature, etc.
Fault protection function (warning and downtime) : Speed/low speed,Speed signal loss warning downtime, low oil pressure alarm downtime, high water temperature alarm downtime, low battery voltage alarm, stop failure alarm, emergency stop alarm, AC voltage/overclocking transfinite alarm, current/power overload alarm, current imbalance alarm, etc.
Parallel function, communication protocol
5. 1 Mains float charger
BAC06A-24V Switching Battery Charger adopts the latest switching power supply device, specially designed for the charging characteristics of lead-acid batteries, and is suitable for long-term supplementary charging of lead-acid batteries (floating charging).The max charging current at 24V is 3A.
5.2 Performance characteristics
The two-stage charging method (the first constant current and then constant voltage mode) is adopted for automatic charging, and the battery is charged in full accordance with the charging characteristics of the battery, which can prevent the lead acid battery from overcharging and maximize the battery life.Applicable to 24V battery charging, the corresponding charger model is BAC06A-24V.With short circuit protection function.Charging voltage, current value can be adjusted.Status LED display: AC power supply indication, charging indication.